Main advantages

  • a powerful controll unit for many applications
  • plastic (lower price) cover of the control unit, durable sensor cover

Applications

  • water treatment
  • mechanical engineering
  • energy engineering
  • food industry
  • agriculture

Product photogallery

Practical installation


Controller specifications

MQI 99 – SMART
Electric conductivity of medium ≥5 µS/cm, for demineralized water ≥20 µS/cm
Input resistance ≥10·10 Ohms
Accuracy of measurement 0,3 % of measured value in range of 10 ÷ 100 % Qmax
Filtration of measurement adjustable in multiple modes
Elimination of small flows adjustable by 0,1 %
Direction of flows Bi-directional measuring indicated by the sign
Zero flow automatic zero point setting
Data recording flow volume archiving, even during power supply failure
Statistics 5 minutes – hourly – daily – monthly for 4 months
Real time clock with calendar inc. leap years until 2099
Values displaying alphanumeric LCD, 2 × 16 characters, with backlight
Control keypad with four buttons
Programmable functions detection of empty pipe
Analog output (active) galvanically separated 4 (0) ÷ 20 mA, (0 ÷ 30 mA) / 300 Ohms
Impulse output (1× relay) flow volume (x·m³) per impulse
Binary output (3× relay) to order (non-inductive load) 30 V/2 A/DC^125 V/0,5 A/AC
Frequency output (open collector) to order nominal rating of 1 kHz/TTL
Communication output (data) to order RS 232 C / RS 485, selectable speed, protocol ELA
Power supply 85 – 260 VAC 50 / 60 Hz, 24 VDC, to order 9 – 36 VDC +10% / -15%, 10 VA
Enclosure IP 65 (NEMA 3)
Ambient temperature −20 °C to +50 °C
Dimensions (height × width × depth) 210 × 160 × 115 mm
Material of case plastics = ABS
Weight 2,0 kg
Cable terminals 3 pcs PG 11 (to order + 2x PG 11)

 Basic dimensions


Technical data of flange sensors

Flange sensor variants design 1 design 2 design 3
Control principle DC pulse
Connecting cable standard 8 m, to order of 16, 24, 32, 40, 48 m, cable can not be extended without consultation with producer
Construction completely welded carbon steel
Inner diameter DN 10 ÷ 1000
Mounting connection flange DIN, ANSI, BS
Enclosure IP 67 / NEMA 5 (IP 68 / NEMA 6)
Measuring tube material stainless steel
Sensor cover material carbon (stainless) steel, surface finish STANDARD acrylic metal-multicomponent paint
Flange material carbon (stainless) steel
Ground rings DN 10 ÷ DN 40 to order for installation in plastic pipe
Sensing electrode material stainless steel (titanium, hastelloy, platinum)
Lining material hard rubber soft rubber teflon PTFE
Maximum temperature of medium * 90 °C 90 °C 130 °C
Standard pressure load
Pressure range **
1,6 MPa
0,6 / 1,0 / 2,5 / 4,0 MPa
1,6 MPa
0,6 / 1,0 / 2,5 / 4,0 MPa
1,6 MPa
0,6 / 1,0 / 2,5 MPa

* Maximum temperature of measured medium consult with producer
** Construction of sensor and type of flange depends on the maximum desired pressure of medium


Technical data of special sensors

Special sensor variants design 1 design 2 design 3
Control principle DC pulse
Connecting cable standard 8 m, to order of 16, 24, 32, 40, 48 m, cable can not be extended without consultation with producer
Construction completely welded carbon steel
Inner diameter DN 10 ÷ 1000
Mounting connection to order special connection , without flange
Enclosure IP 67 / NEMA 5 (IP 68 / NEMA 6)
Measuring tube material stainless steel
Sensor cover material carbon (stainless) steel
Flange material to order
Ground rings DN 10 ÷ DN 40 to order for installation in plastic pipe
Sensing electrode material stainless steel (titanium, hastelloy, platinum)
Lining material hard rubber soft rubber teflon PTFE
Maximum temperature of medium * 90 °C 90 °C 130 °C
Standard pressure load
Pressure range **
1,0 MPa
0,6 / 1,0 MPa
1,0 MPa
0,6 / 1,0 / MPa
1,0 MPa
0,6 / 1,0 MPa

* Maximum temperature of measured medium consult with producer
** Construction of sensor and type of flange depends on the maximum desired pressure of medium