CREATE REQUEST


Applications

  • non-contact continuous fluid level sensing
  • separate function or in cooperation with the MHU 99, MHU 99-S, MHU 99-C control unit
  • digital signal processing with powerful filter
  • control core – pair of microprocessors
  • adjustable measuring window
  • internal digital ambient temperature compensation
  • high protection IP 68

Product photogallery


Technical data – control unit

TypE PU 500 PU 2000 PU 4000 PU 6000
Installation height 50 cm 200 cm 400 cm 600 cm
Measuring range 0—40 cm 0—180 cm 0—350 cm 0—520 cm
Resolution 0,02 cm
Accuracy of measurement 0,4 % z rozsahu
Linearity ±0,2 cm
Beam angle 10°
Working temperature −20 °C až +50 °C
Storage temperature −40 °C až +85 °C
Power supply 12—25 VDC/100 mA
Current output (active) 4/0—20 mA / generally adjustable in the range 0—30 mA / 300 Ohmů, galvanically isolated
Binary output open collector max. 30 VDC / 50 mA
Binary output function + comparator or band switch (with hysteresis)
+ fault indication or startup phase
+ pulse output (period linearly proportional to altitude)
Communication line RS 485, 1200 — 19200 Bd, ASCII protocol
Protection IP 68 (NEMA 6)
Dimensions (height x width × depth) ∅74 × – × 152 mm
Weight 1,6 kg
Connection cable 8 × 0,5 mm2 CU, 4m long from probe
Communication SW WINDOWS
Mounting console ELA