CREATE REQUEST


Main advantages

  • powerful converter for many applications
  • plastic housing of main unit (lower price), resistant cover

Applications

  • water treatment
  • mechanical engineering
  • energy engineering
  • food industry
  • agriculture

Product photogallery

Practical installation


Technical data – main unit

MhU 99 2MhU 99
Input 1× ultrasonic probe 2× ultrasonic probe
Filtration of measuring adjustable
Data recording archiving even during power supply failure
Statistics 5 min. – hourly – daily – monthly
Real time clock with calendar inc. leap years until 2099
Service hours yes (depending on the probe condition)
Values displaying alphanumeric LCD, 2 × 16 characters, with backlight
Control keypad with four buttons
Programmable functions adjustable comparison of measured value
Analog output (active) galvanically separated 4 (0) ÷ 20 mA, (0 ÷ 30 mA) / 300 Ohms
Binary output (4 × relay) to order (non-inductive load) 30 V/2 A/DC^125 V/0,5 A/AC
Communication output (data) to order RS 232 C / RS 485, selectable speed, protocol ELA
Power supply 85 – 260 VAC 50 / 60 Hz, 24 VDC, to order 9 – 36 VDC +10% / -15%, 10 VA
Enclosure IP 65 (NEMA 3)
Ambient temperature −20 °C to +50 °C
Dimensions (height × width × depth) 210 × 160 × 115 mm
Material of case plastics = ABS
Weight 2,0 kg
Cable terminals 3 pcs PG 11 (to order + 2x PG 11)

Basic dimensions


Technical data of sensors

Type of probe DU 500 DU 2000 DU 4000 DU 6000
Installing height 50 cm 200 cm 400 cm 600 cm
Measuring range 0—40 cm 0—180 cm 0—350 cm 0—520 cm
Level resolution 0,02 cm
Accuracy of measurement 0,4 % of scale
Linearity ±0,2 cm
Radiation angle 10°
Operating temperature −20 °C to +50 °C
Storage temperature −40 °C to +85 °C
Power supply 12—25 VDC/100 mA
Enclosure IP 68 (NEMA 6)
Dimensions (height × width × depth) ∅74 × – × 152 mm
Weight 1,2 kg
Connecting cable 4 × 1 mm2 CU, firmly conducted from probe of length of 4 m
Fixation console ELA

Basic dimensions