«Control unit with enclosure IP 65»

You are here: ProductsUltrasonic flow meters MQU 99, MQU 99-S, MQU 99-C ⇒MQU 99: SEPARATE DESIGN

MQU 99/2MQU 99: example of system with control unit and separate 1 or 2 sensors with ELA adaptor

Merits

  • efficient control unit for many aplications
  • plastic (lower price) cover of control unit, resistant cover of sensor

Field of application

  • water service
  • engineering
  • energetics
  • food industry
  • agriculture

Technical data of control unit

  MQU 99 2MQU 99
Input 1× ultrasonic probe 2× ultrasonic probe
Accuracy of measurement 0,3 % of measured value in range of 10 ÷ 100 % Qmax
Filtration of measurement digital, adjustable in multiple modes
Elimination of small flows adjustable by 0,1 %
Data recording flow volume archiving, even during power supply failure
Statistics 5 minutes - hourly - daily - monthly for 2 months
Real time clock with calendar inc. leap years until 2099
Service hours yes (depending on the probe condition)
Values displaying alphanumeric LCD, 2 × 16 characters, with backlight
Control keypad with four buttons
Programmable functions setting translation curve using the formula, flooding the lower neck of manger, comparators, failure probe etc.
Analog output (active) galvanically separated 4 (0) ÷ 20 mA, (0 ÷ 30 mA) / 300 Ohms
Impulse output (1× relay) flow volume (x·m³) per impulse
Binary output (3× relay) to order (non-inductive load) 30 V/2 A/DC^125 V/0,5 A/AC
Communication output (data) to order RS 232 C / RS 485, selectable speed, protocol ELA
Power supply 85 - 260 VAC 50 / 60 Hz, 24 VDC, to order 9 - 36 VDC +10% / -15%, 10 VA
Enclosure IP 65 (NEMA 3)
Ambient temperature -20 °C to +50 °C
Dimensions (height × width × depth) 210 × 160 × 115 mm
Material of case plastics = ABS
Weight 2,0 kg
Cable terminals 3 pcs PG 11 (to order + 2x PG 11)

practical assembly

basic dimensions


Technical data of sensors

Type of probe PU 500 PU 2000 PU 4000 PU 6000
Installing height 50 cm 200 cm 400 cm 600 cm
Measuring range 0—40 cm 0—180 cm 0—350 cm 0—520 cm
Level resolution 0,02 cm
Accuracy of measurement 0,4 % of scale
Linearity ±0,2 cm
Radiation angle 10°
Operating temperature −20 °C to +50 °C
Storage temperature −40 °C to +85 °C
Power supply 12—25 VDC/100 mA
Enclosure IP 68 (NEMA 6)
Dimensions (height × width × depth) ∅74 × - × 152 mm
Weight 1,2 kg
Connecting cable 4 × 1 mm2 CU, firmly conducted from probe of length of 4 m
Fixation console ELA
praktická motá�

practical assembly

basic dimensions

basic dimensions