You are here: Products ⇒ SmQI and SmQU software
Communication software for data collection SmQI and SmQU
Field of application
- progressive, remote communication with up to 255 pieces of ELA meters from one PC (PDA, notebook, etc.)
- indication the actual status of display unit of flow meters and level meters ELA
- storage, archiving, printing and export of measured data for the purpose: statistics, billing, etc.
- service and inspection activities
Basic specifications of each transmission networks
| Type of communication | RS 232 | RS 485 | Bluetooth | |
|---|---|---|---|---|
| Guaranteed maximum reach | 10 m | 500 m | 100 m direct visibility, 10 m - 15 m in building | |
| Type of transmission | data line 3 wire | data line 2 wire | Bluetooth 2.0 IEEE-802.15.1., Class 1, radio interface 2.4 GHz ISM, SPP profile | |
| Output interface in ELA control unit | RxD=terminal7, (input) TxD=terminal8, (output) GND=terminal7, (ground) - or standard CANON9 | A=terminal7 B=terminal8 | omnidirectional antenna 2 dBi, vertical polarization-linear | |
| Communication between PC (master) and ELA products (slave) | two points (point-to-point) | progressive, many points-32 (point-to-multipoint) | progressive, many points-255 (point-to-multipoint) | |
| PC system requirements | WINDOWS 98 - WIN XP, port compatible with RS 232, USB version 2.0 | |||
Graphic scheme of available communications for ELA data transmission and data collection.
Basic functions of SmQI, SmQU software
1. parallel view of data from control unit to the remote PC
2. transfer and storage of archived data from the control unit MQI, MQU to PC
3. processing of data stored on PC and display in graphical or numerical form on the monitor and output to a printer
4. export stored data to a file (CSV) - the possibility of processing (eg excel) according to their own requirements and standards for visualization on a PC
- Manual: Software for data collection SmQIU (90 kB)
- Manual: Software for data collection SmQIU - supplement (247 kB)
- Protocol: SmQIU (330 kB)